MOLD-CLOSE Failure
  1. Ejector doesn't reach its EJECTOR-RETRACT-END position;
  2. Safety gate is not closed;
  3. Limit switches of safety gate are damaged;
  4. MOLD-CLOSE-HIGH-PRESSURE, MOLD-CLOSE-END fail;
  5. Data setting of mold close wrong;
  6. Data setting of core pulling wrong.
MOLD-OPEN Failure
  1. MOLD-OPEN-END fails;
  2. Data setting of MOLD-OPEN wrong(ST.25 too large, C3 always on, MOLD-OPEN can not stop);
Ejector Failure
  1. EJECTOR-RETRACT-END, EJECTOR-ADVANCE-END fail;
  2. Eject number is zero.
Injection Failure under Auto Mode
  1. Barrel temperature too low;
  2. NOZZLE-ADVANCE-END failure.
Charge Failure
  1. Temperature too low;
  2. CHARGE-END fails.
Core-pulling Failure under Auto Mode
  1. DCS220/230: BIT SW1-03 is not set ON;
  2. Position of core pulling is within MOLD-CLOSE-HIGH-PRESSURE.
MOLD-ADJUST Failure
  1. MOLD-ADJUST fails;
  2. Data setting of MOLD-ADJUST wrong;
Cooling Failure
  1. Charge too long time;
  2. Increase cooling time.
Action Stops Very Slowly
  1. RAMP of Pressure, flow too large.
 